Robust Encoder

A special feature of our house is the ROBUST ENCODER SYSTEM AWG / AWS.

It has been specially developed for use in special environments, such as in heavy industry, steel mills, mines, cranes, in ship and lock building and in the chemical and food processing industries. All housing parts, flange, cap, tube, tubular housing with 5 mm wall thickness are made of stainless steel. The shaft load of up to 1,500 N. The installation dimensions of the system are compatible to the known encoders. Both extreme temperatures from -40 ° C to + 200 ° C and exposure to dirt, water, alkalis and acids are not a problem. The protection class is IP 67. Because of the wide variety of options and accessories, use in pretty much any area is possible especially food-grade customs.

In the AWG - housings can be both incremental encoder and absolute encoder with SSI interface and all fieldbus connections (CAN -BUS , PROFIBUS, ETHERNET Powerlink, INTERBUS) block. We manufacture the ROBUST ENCODER SYSTEM AWG as a redundant encoder system with double or triple donors , in the combination of digital and analog encoders.

The area of ​​application for the ROBUST ENCODER AWG 102 with through hollow shaft is the transmission of the rotational movement to already mounted ROBUST ENCODER Systems, limit switch, cam switches, speedometers or other devices that receive rotary motion.

Do not be afraid to talk to us if you do not find your desired encoder, inform our technicians will gladly advise you .

Robust Encoder

Method Case diameter Shaft diameter Resolution
Optical incremental ø 100 mm ø 10 mm up to 500.000
Protection class Flange diameter Channels Temperature range
IP 67 ø 100 mm 3, 6 -40 .. +200°C optional

Method Case diameter Shaft diameter Resolution
Optical incremental ø 100 mm ø 10 mm up to 500.000
Protection class Flange diameter Channels Temperature range
IP 67 ø 100 mm 3, 6 -40 .. +125°C optional

Method Case diameter Shaft diameter Resolution
Optical incremental ø 100 mm - up to 500.000
Protection class Flange diameter Channels Temperature range
IP 67, IP 40 - 3, 6 0 ... +80°C

Method Case diameter Shaft diameter Resolution
Optical absolute ø 100 mm ø 10 mm 4096 = 12 bit
8192 = 13 bit
65536 = 16 bit
Protection class Flange diameter Channels Temperature range
IP 67 ø 100 mm -40 ... +125°C optional

Method Case diameter Shaft diameter Resolution
Optical absolute ø 100 mm -
Protection class Flange diameter Channels Temperature range
IP 67, IP 40 - 0 ... +85°C